Suspending DR PLD7100 is a medical procedure used in critical care settings to provide temporary circulatory support for a patient in need of advanced life support. It involves the utilization of a specialized medical device known as the PLD7100 (Portable Left Ventricular Assist Device) to assist the heart’s pumping function.
Description of Suspending DR PLD7100 Procedure:
- Indication: The procedure is typically indicated for patients with severe heart failure, cardiogenic shock, or other cardiac conditions that result in the heart’s inability to pump blood effectively. These patients may be experiencing life-threatening hemodynamic instability.
- Preparations: Before initiating the procedure, a thorough assessment of the patient’s medical history, cardiac condition, and overall health status is conducted. The medical team should ensure that the patient meets the criteria for PLD7100 support and that all necessary consents have been obtained.
- Anesthesia: The procedure usually requires the patient to be under general anesthesia to ensure comfort and minimize patient movement during the device placement.
- Access: The medical team gains access to the patient’s circulatory system by inserting appropriate vascular catheters into the large blood vessels, such as the femoral artery and femoral vein, or via a more central approach.
- Device Implantation: The PLD7100 is a compact, surgically implantable left ventricular assist device designed to provide circulatory support. It is connected to the heart’s left ventricle, which is responsible for pumping oxygenated blood to the rest of the body.
- Device Activation: Once the PLD7100 is properly implanted and connected, it is activated. The device starts assisting the patient’s heart by pumping blood from the left ventricle into the aorta, thereby enhancing overall cardiac output and perfusion to vital organs.
- Monitoring: Throughout the suspension period, the medical team closely monitors the patient’s hemodynamic parameters, vital signs, and device function. They also manage any potential complications that may arise during the procedure.
- Duration: The duration of PLD7100 support varies depending on the patient’s specific medical condition and their response to therapy. In some cases, the device may be used for a few days to weeks while awaiting heart transplant or for the heart to recover its function.
- Weaning: Once the patient’s cardiac function improves sufficiently, the medical team gradually weans them off the PLD7100 support. This process involves careful assessment of the patient’s condition and monitoring the heart’s ability to resume its pumping function effectively.
It’s important to note that Suspending DR PLD7100 is a highly specialized procedure performed by skilled and experienced medical professionals in specialized cardiac care facilities. The decision to utilize this circulatory support device is made based on the patient’s individual medical needs and the recommendation of a multidisciplinary medical team.